MKTD Series 5A-30A Solar Charge Controller
MKTD Series Solar Charge Controller 5A,10A,15A,20A,30A
Scope of Application | |||||
The charge regulator is only suitable for regulating photovoltaic solar modules. Never connect another charging source to the charge regulator. This can destroy the regulator and / or source. | |||||
The regulator is only suitable for the following chargeable 12V or 24V battery types: | |||||
-Lead storage batteries with liquid electrolytes | |||||
-Sealed lead storage batteries; AGM, GEL | |||||
Important!The regulator is not suited for nickel Cadmium, nickel metal hydride, lithium ions or other rechargeable or non-rechargeable batteries. | |||||
The regulator may only be used for the particular solar applications provided.Also,observe that the permitted, model-specific, nominal currents and voltages are not exceeded. | |||||
Installation | |||||
Install the regulator near the battery on a suitable surface. The battery cable should be as short as possible and have a suitable cable diameter size to minimize loss, e.g. 4 mm² at 20 A and 2m length.A temperature compensated final charge voltage will extend the batteries lifetime and uses the optimum charge capacity. | |||||
Do not install the controller to direct sunlight. | |||||
To ensure the air confection on each side keep a distance of 10 cm to the regulator. | |||||
Connecting the Regulator | |||||
1.Connect the battery to the charge regulator - plus and minus | |||||
2.Connect the photovoltaic module to the charge regulator - plus and minus | |||||
3. Connect the consumer to the charge regulator - plus and minus | |||||
The reverse order applies when deinstalling! | |||||
An improper sequence order can damage the controller! | |||||
System indicator | |||||
1.Solar Indicator | |||||
Off:without enough sun,charge off. | |||||
Fast flashing:Buck/equalize charge | |||||
Constant on:Acceptance charge | |||||
Slow flashing:Float charge | |||||
2.Battery Indicator | |||||
Green:Battery power is full(V>13.4V) | |||||
Orange:Battery power is middle(12.4V<V<13.4V) | |||||
Red:Battery power is low(11.2V<V<12.4V) | |||||
Red-flashing:Battery over discharge.(11.2V<V) | |||||
3.Consume Indicator | |||||
Off:Controller output closed | |||||
On:Output normal | |||||
Slow Flashing: Continues over-current | |||||
Fast Flashing:Short-circuit | |||||
4.System mode | |||||
5.Setting button | |||||
Technical parameter | |||||
Model | MKTD1205 | MKTD1210 | MKTD1215 | MKTD1220 | MKTD1230 |
Rated charging current | 5A | 10A | 15A | 20A | 30A |
Rated discharging current | 5A | 10A | 15A | 20A | 30A |
Short-current protection | 40A | 40A | 40A | 40A | 60A |
System voltage | 12V/24V Auto adapt | ||||
Over current protection | <1.3 maintain for 60s | ||||
<1.6 maintain for 5s | |||||
>1.6 shut down immediately | |||||
Stand-by lost | <5mA | ||||
Charge voltage drop | ≤0.26V | ||||
Discharge voltage drop | ≤0.15V | ||||
Max solar panel votlage | 21V | ||||
Operating temperature | -35℃ to +55℃ | ||||
Equalize charging voltage | 14.8V | ||||
Bulk charging voltage | 14.5V | ||||
Acceptance charging voltage | 14.2V | ||||
Float charging | 13.8V | ||||
Charge return voltage | 13.2V | ||||
Discharge stop voltage | 11.2V | ||||
Discharge return voltage | 12.6V | ||||
Temperature compensation | N/C | ||||
Control mode | PWM( Pulse Width Modulation ) | ||||
Maximum wire size | 12AWG | ||||
Size/weight | 133×70×35mm/150g |
PWM Solar charge controller
Economic solar controller charge lead acid battery
12V/24V auto work
Economic solar controller charge lead acid battery
12V/24V auto work