MKLX Series 10A-30A LCD Solar charge controller
TECHNICAL PARAMETER
TECHNICAL PARAMETER | ||||||
Model Number | MKLX | |||||
System Voltage | 12V/24Vauto | 48V | ||||
MAX.PV input | <50V | <100V | ||||
Rated current | 10A | 20A | 30A | 10A | 20A | 30A |
USB output | 5V/2A | |||||
Charge control | PWM | |||||
Standby lost | <15mA@12V <10mA@LVD | |||||
Working temp. | -20~+60 ℃ | |||||
Size/Weight | 133*70*33mm /150g | |||||
VOLTAGE PARAMETER | ||||||
Battery | B01 | B02 | B03 | B04 | B05 | B06 |
type | General | Li- ion | LIFePO4 | sealed | GEL | Flooded |
Lead acid | ||||||
HVD | 16V | 16V | 16V | 16V | 16V | 16V |
HVR | 15V | 15V | 15V | 15V | 15V | 15V |
Bulk(Absorption) | 13.7V | 12.3V | 14.0V | 14.4V | 14.2V | 14.6V |
Equalize | - | - | - | 14.6V | - | 14.8V |
Float | 13.7V | 12.3V | 14.0V | 13.7V | 13.7V | 13.7V |
Charge return | 13V | 12V | 13V | 13V | 13V | 13V |
LVR | 12.0V | 10.5V | 12.0V | 12.6V | 12.6V | 12.6V |
LVD | 10.7V | 9.5V | 11.2V | 10.7V | 10.7V | 10.7V |
*all voltage X2 ,X4 while using 24V /48V system. | ||||||
*Product specifications are subject to change without prior notice. |
Rated current:10A/20A/30A
Battery voltage sutable: 12/24V 48V
Maximum solar input voltage: <50V
Battery voltage sutable: 12/24V 48V
Maximum solar input voltage: <50V